ADM1LE

ADM1LE

ADM1LE series residual circuit breaker is suitable for AC50/60Hz, rated voltage 415V, rated current 10A to 800A circuit. Its main function is to provide indirect contact protection to people who are in danger of electric shock.

ADM1LE

Moulded Case Circuit Breaker+EL


Application

ADM1LE series residual circuit breaker is suitable for AC50/60Hz, rated voltage 415V, rated current 10A to 800A circuit. Its main function is to provide indirect contact protection to people who are in danger of electric shock.

The rated residual operating current does not exceed 30mA, can also be used as a supplementary protection for direct contact when other protective measures fail, but not as the only direct contact protection. Besides, it can also be used to prevent electrical fires caused by contact fault currents, and protect the overload and short circuit of the line, and also be used for infrequent conversion of the circuit.

It is in conformity of IEC60947-2 standard.

Ambient temperature: -5℃ to +40℃


Main Technical Data

Model NO.

Rated Current(A)

Rated Voltage

Rated Residual  Operating Current(mA)

Icu(kA)

415V/690V

Ics(kA)

415V/690V

ADM1LE-100

S/H

16,20,25,32,40,50,63,80,100

3P/4P: 415V

100,300,500

S:30

H:50

S:15

H:25

ADM1LE-250

S/H

100,125,140,160,180,200,

225,250

3P/4P: 415V

100,300,500

S:30

H:50

S:15

H:25

ADM1LE-400

S/H

200,225,250,315,

350,400

3P/4P: 415V

100,300,500

S:50

H:65

S:25

H:32.5

ADM1LE-630

S/H

400,500,630

3P/4P: 415V

100,300,500,1000

S:50

H:65

S:25

H:32.5

ADM1LE-800

S/H

630,700,800

3P/4P: 415V

100,300,500,1000

S:50

H:70

S:25

H:35

S-Standard Type;

H-High Breaking Ability;


Classification

Installation Type

Vertical installation, Horizontal installation

Wiring Type

Front connection, Back connection, Plug-in type

Handle Type

Direct operated handle , extend rotary handle, Motor operator

Tripping Type

Thermal magnetic tripping, Electronic tripping

Number of poles

3P, 4P


Tripping Characteristic

Electromagnetic tripping for Distribution protection

Rated Current(A)

Thermal tripping(Ambient temperature +40)

Electromagnetic trip action current (A)

1.05In Cold state

1.30In Thermal state

10In63

1

1

10In±20%

63In100

2

2

10In±20%

100In800

2

2

10In±20%

 

Electromagnetic tripping for Motor protection

Rated Current(A)

Thermal tripping(Ambient temperature +40℃)

Electromagnetic trip action current (A)

1.0In Cold state

1.2In Thermal state

1.5In Thermal state

7.0In Cold state

10In800

≥2h

≤2h

8min

6Tp20s

12In±20%


Residual Current Protection Characteristic Curve


Outline and Dimension

Model NO.

Width

(mm)

Length

(mm)

Height

(mm)

ADM1LE-100 3P

92

150

92

ADM1LE-100 4P

122

150

92

ADM1LE-250 3P

107

165

90

ADM1LE-250 4P

142

165

90

ADM1LE-400 3P

150

257

106.5

ADM1LE-400 4P

198

257

106.5

ADM1LE-630/800 3P

210

280

115.5

ADM1LE-630/800 4P

280

280

115.5

 

 

 

 

 

 

 

 

 

 

 

 

 






Previous: IS-ADM1